CCP - channel calibration parameters

Attention: Retained for backward compatibility only in version 2.7. This is used only in the CD Channel Definition data type, which has been retained for backward compatibility only in v2.7.

HL7 Component Table - CCP - channel calibration parameters
Seq# Description Data Type Usage Vocabulary Length C.LEN Flags
CCP
1 Channel Calibration Sensitivity Correction Factor NM O   6
2 Channel Calibration Baseline NM O   6
3 Channel Calibration Time Skew NM O   6

Components: <Channel Calibration Sensitivity Correction Factor (NM)> & <Channel Calibration Baseline (NM)> & <Channel Calibration Time Skew (NM)>


CCP-1: Channel Calibration Sensitivity Correction Factor (NM)

Definition: This component defines a correction factor for channel sensitivity, which may be derived from the last calibration procedure performed. The actual channel sensitivity is the nominal channel sensitivity given in the previous component multiplied by the unitless correction factor.

CCP-2: Channel Calibration Baseline (NM)

Definition: This component defines the actual channel baseline (the data value which corresponds to a nominal input signal of zero). The actual baseline may differ from the ideal because of a dc offset in the amplifier connected to the ADC. The actual baseline values for all channels (which need not be integers) may be determined at the time of calibration as the average digitized values obtained when a zero input signal is connected to each channel.

CCP-3: Channel Calibration Time Skew (NM)

Definition: This component defines the time difference between the nominal sampling (digitization) time (which would be the same for all channels) and the actual sampling time of the channel, in seconds (or fractions thereof). This value will differ from zero when all channels in the montage are not sampled simultaneously, as occurs in systems, which sample successive channels at regular time intervals. This value may be determined from a calibration procedure in which an identical time-varying signal is applied to all channels and interchannel time differences are estimated, or more commonly it may be taken from the manufacturer’s specifications for the digitizing system used. For example, for a system which samples successive channels at regular time intervals t, the time skew of channel number n would be (n-1)t. The actual time of sampling (digitization) of sample number m of channel number n in such a system would be R + (m-1)/f + (n-1)t, where R is the reference time at the start of the epoch and f is the channel sampling frequency (t < 1/f).