The RXV segment details the pharmacy or treatment application’s encoding of specific infusion order parameters
Seq# | Data Element Name | DataType | Usage | Vocabulary | Cardinality | Item # | Length | C.LEN | Flags |
---|---|---|---|---|---|---|---|---|---|
RXV | |||||||||
1 | Set ID - RXV | SI | O | [0..1] | 03318 | ||||
2 | Bolus Type | ID | R | [1..1] | 03319 | [1..1] | |||
3 | Bolus Dose Amount | NM | O | [0..1] | 03320 | ||||
4 | Bolus Dose Amount Units | CWE | O | [0..1] | 03321 | ||||
5 | Bolus Dose Volume | NM | O | [0..1] | 03322 | 20 | # | ||
6 | Bolus Dose Volume Units | CWE | O | [0..1] | 03323 | ||||
7 | PCA Type | ID | R | [1..1] | 03324 | [1..2] | |||
8 | PCA Dose Amount | NM | O | [0..1] | 03325 | 20 | # | ||
9 | PCA Dose Amount Units | CWE | O | [0..1] | 03326 | ||||
10 | PCA Dose Amount Volume | NM | O | [0..1] | 03327 | 20 | # | ||
11 | PCA Dose Amount Volume Units | CWE | O | [0..1] | 03328 | ||||
12 | Max Dose Amount | NM | O | [0..1] | 03329 | 20 | # | ||
13 | Max Dose Amount Units | CWE | O | [0..1] | 03330 | ||||
14 | Max Dose Amount Volume | NM | O | [0..1] | 03331 | 20 | # | ||
15 | Max Dose Amount Volume Units | CWE | O | [0..1] | 03332 | ||||
16 | Max Dose per Time | CQ | R | [1..1] | 03333 | ||||
17 | Lockout Interval | CQ | O | [0..1] | 03334 | ||||
18 | Syringe Manufacturer | CWE | O | [0..1] | 03339 | ||||
19 | Syringe Model Number | CWE | O | [0..1] | 03385 | ||||
20 | Syringe Size | NM | C | [0..1] | 03386 | 20 | # | ||
21 | Syringe Size Units | CWE | C | [0..1] | 03431 | ||||
22 | Action Code | ID | O | [0..1] | 00816 | [2..2] |
Definition: For the first timing specification transmitted, the sequence number shall be 1; for the second timing specification, it shall be 2; and so on.
Definition: This field identifies the type of bolus being ordered. See HL7 Defined Table 0917 – Bolus Type in Chapter 2C, Code Tables, for example values.
Definition: This field contains the ordered bolus amount. For example, if the ordered bolus is 50 mg, this field contains the value of 50.
Definition: This field indicates the amount units associated with the bolus dose amount. The preferred coding system is MDC; UCUM are also acceptable. Refer to Table 0767 - Bolus Dose Amount Units in Chapter 2C for valid values.
Examples:
263890^MDC_DIM_MILLI_G^MDC
mg^milligram^UCUM
Definition: This field defines the volume measurement for the ordered bolus amount. For example, if the ordered bolus is 5 ml, this field contains the value of 5.
Definition: This field indicates the amount units associated with the bolus dose volume. The preferred coding system is MDC; UCUM are also acceptable. Refer to Table 0768 - Bolus Dose Volume Units in Chapter 2C for valid values.
Examples:
263890^MDC_DIM_MILLI_G^MDC
mg^milligram^UCUM
Definition: This field identifies the type of bolus being ordered. See HL7 Defined Table 0918 – PCA Type in Chapter 2C, Code Tables, for example values.
Definition: This field contains the order’s PCA dose amount. Example: if the ordered bolus is 3 mg, this field contains the value of 3.
Definition: This field indicates the amount units associated with the PCA dose amount. The preferred coding system is MDC; UCUM are also acceptable. Refer to Table 0769 - PCA Dose Amount Units in Chapter 2C for valid values.
Examples:
263890^MDC_DIM_MILLI_G^MDC
mg^milligram^UCUM
Definition: This field defines the volume measurement for the ordered PCA amount volume. For example, if the ordered bolus is 5 ml, this field contains the value of 5.
Definition: This field indicates the amount units associated with the PCA dose volume. The preferred coding system is MDC; UCUM are also acceptable. Refer to Table 0770 - PCA Dose Amount Volume Units in Chapter 2C for valid values.
Examples:
263890^MDC_DIM_MILLI_G^MDC
mg^milligram^UCUM
Definition: This field contains the order’s maximum dose amount. For example, if the ordered bolus is 50 mg, this field contains the value of 50.
Definition: This field indicates the amount units associated with the maximum dose volume. The preferred coding system is MDC; UCUM are also acceptable. Refer to Table 0772 - Max Dose Amount Units in Chapter 2C for valid values.
Examples:
263890^MDC_DIM_MILLI_G^MDC
mg^milligram^UCUM
Definition: This field defines the volume measurement for the ordered max dose amount. For example, if the ordered bolus is 5 ml, this field contains the value of 5.
Definition: This field indicates the amount units associated with the maximum dose volume. The preferred coding system is MDC; UCUM are also acceptable. Refer to Table 0773 - Max Dose Amount Volume Units in Chapter 2C for valid values.
Examples:
263890^MDC_DIM_MILLI_G^MDC
mg^milligram^UCUM
Definition: This field contains the time unit expression of the lock out parameter. For example, if the ordered max dose per time is 4 hours, this field format is "4^h&hours&UCUM".
Definition: This field contains the length of time that must expire between deliveries of PCA doses. For example, if the ordered max dose per time is 10 minutes, this field format is "10^min&minute&UCUM".
Definition: This field contains the manufacturer of the syringe containing the ordered medication.
Definition: This field contains the model number of the syringe containing the ordered medication.
Definition: This field contains the syringe’s numeric total volume size.
Definition: This field indicates the amount units associated with the syringe size. The preferred coding system is MDC; UCUM are also acceptable.
Examples:
263890^MDC_DIM_MILLI_G^MDC
mg^milligram^UCUM
Definition: The intended handling by the receiver of the infusion order is represented by this segment. Refer to HL7 Table 0206 – Segment Action Code in Chapter 2C, Code Tables, for valid values.